| Performance | |
|---|---|
| Analog Inputs (X and Y-Axis) | AC/DC coupled, Current (ICP) or Voltage, Inverting/Non-Inverting (software selectable) |
| Sampling Rate | 20 kHz |
| Voltage Gain (Incremental Steps) | x0.5, 1.0, 2.0, 2.5, 4.0, 5.0, 8.0, 16.0 |
| Environmental | |
| Operating Temperature | 15 to 50°C (60 to 120°F) |
| Electrical | |
| Voltage supply | 85-264VAC – 47-63Hz |
| Broadband Electrical Noise (1 Hz to 10kHz) | 20 µV rms |
| Input 1 through 8 | 24VDC discrete input |
| Output 1 and 5 | 125VAC @ 3A – relay, dry contact |
| Output 2 and 6 | 30VDC @ 2A – relay, dry contact |
| Output 3 and 4 | 24VDC @ 400mA – MOSFET |
| Physical | |
| Mounting | Universal mounting bracket |
| Dimensions – H x W x L | 65mm x 190mm x 115mm |
| Electrical Connector - Sensor Input | SMA, M12 |
| Electrical Connector -Digital Inputs/Outputs | M12, 4/5-pin male/female |
| Communications | (all unsupported in the current release) |
| USB (for future use) | USB 2.0 |
| Ethernet (for future use) | RJ45 - Auto-Sensing 10Base-T or 100Base-TX – User configurable DHCP or Static IP |
| RS232 (for future use) | Optional RS232 communication adapter available |
Note: This product conforms to applicable European Directives for CE marking. OES reserves the right to make changes without further notice herein.
Proactive system measures the process variance on a machine for each production cycle, detecting even small problems at the source… well before they become quality issues.
If a process (including inputs, force, and tooling) is known to be capable of producing only good parts, and the process is consistent and repeatable, then the output of good parts should be consistent also. It's simply about determining the quality and stability of the process.